english
drk-504 moisture analyzer supports the measurement of moisture content in the full range including volumetric method and coulometric method, and meets the measurement needs of different users of constant moisture and trace moisture.
l supports the measurement of moisture content in the full range including volumetric method and coulomb method to meet the measurement needs of different users of constant moisture and trace moisture;
l dot-matrix lcd display, key operation, simultaneous control or separate control by computer chinese software; real-time display of relevant test methods and test results;
l "conversational" operation steps to easily complete titration settings and process operations;
l pollution-free measurement and analysis process: anti-leakage device and waste bottle anti-suckback device; automatic liquid inlet, liquid discharge, kf reagent mixing and automatic cleaning functions, anti-titration cup solution overflow protection function; to prevent users from directly contacting kf reagents, to ensure the safety of measurement and use personnel and the environment;
l support pre-titration, automatic titration, manual titration, constant titration, kf titer determination and other titration modes to meet the analysis of different types of samples;
l supports a variety of burette types, and supports re-calibration of burette coefficients;
l users can choose mg, mg/l, %, ppm and other measurement result units as needed; the instrument supports glp specification, supports storage of 200 sets of constant and trace moisture measurement data; supports data storage, deletion, viewing, printing or output;
l with power-off protection function and kf reagent failure detection and reminder function;
l support rs232 serial printer to print measurement results;
l support firmware upgrade and software upgrade, allowing function expansion.
model
technical parameters | drk-504 |
measuring range | volumetric method: (0.1~250.0) mg; coulometric method: 10μg~20mg |
measurement results | volumetric method: mg, mg/l, %, ppm four; coulometric method: μg, mg, %, ppm, mg/l, μg/ml. |
polarization current | 1µa±0.2µa;50µa±10µa; |
electrolytic current | coulomb method: 10 ma, 20 ma, 50 ma, 100 ma four current files. |
indication error | coulomb method: ±(5% verification point 3) μ3 |
repeatability | capacity method: ≤0.5% coulometric method: relative standard deviation (rsd) of the measured value at 100μg point ≤3% |
dimensions (mm), weight (kg) | 340×400×400(l×w×h); about 10 |